Brocade Fabric Watch Administrators Guide (Supporting Fabric OS v7.3.0) User Manual

Page 76

Advertising
background image

• Link Failure Count
• Loss of Synchronization Count
• Primitive Sequence Protocol Error
• Invalid Transmission Word
• Invalid CRC Count
• Class 3 Discards

The only ports which fall into the FCU_Port subclass are internal copper-based ports on embedded
switches. Copper-based ICL ports are not part of the FCU_Port subclass, and optical ICL ports are not
part of the FOP_Port subclass.

FOP_Port and FCU_Port subclass default settings

TABLE 18

Area

Description

Default threshold
settings

Default alarm
settings

Threshold state

Cyclic
redundancy check
(CRC with good
EOF (crc g_eof)
markers)

Monitors the number of
CRC errors.

Unit: Errors

Time Base: minute

Low: 0

High: 1000

Buffer: 100

Below: 0

Above: 0

Informative

Out_of_range

Invalid
transmission
words (ITW)

Monitors the number of
invalid words transmitted.

For Fabric OS 7.1.0 and
later, the ITW counter
includes a physical coding
sublayer (PCS) violation.
ITW violations can occur
due to an ITW violation, a
PCS violation, or both.

Unit: Errors

Time Base: minute

Low: 0

High: 1000

Buffer: 100

Below: 0

Above: 0

Informative

Out_of_range

Class 3 discards
(C3TX_TO)

Class 3 discards frames due
to time-out or destination
unreachable.

Unit: Errors

Time Base: minute

Low: 0

High: 5

Buffer: 0

Below: 0

Above: 0

Informative

Out_of_range

Link loss

Monitors the number of link
failures.

Unit: Errors

Time Base: minute

Low: 0

High: 500

Buffer: 50

Below: 0

Above: 0

Informative

Out_of_range

Signal loss

Monitors the number of
signal loss errors.

Unit: Errors

Time Base: minute

Low: 0

High: 5

Buffer: 0

Below: 0

Above: 0

Informative

Out_of_range

Port Monitoring

76

Fabric Watch Administrators Guide

53-1003142-01

Advertising