Burcam 300521 HOT WATER RETENTION PUMPING SYSTEM (GENIE) User Manual

Page 4

Advertising
background image

STEP 15

STEP 13

STEP 16

STEP 14

STEP 17

STEP 18

4

Screw the bypass valve at an appropriate place, with the hot water side on left and the vertical

port facing to the faucet.
From these vertical ports, connect the 1/2’’ to 3/8’’ flexible hoses to the faucet, respectively for

the hot and cold sides.
Then, connect the 1/2’’ to 1/2’’ flexible hoses from water supplies to the side ports of the

bypass valve, respectively for the hot and cold sides
Open the sink supply valves and close the hot water faucets previously opened to drain the

hot water pipe.
Open the water supply to the water heater. Then open the ball valves before and after the

pump.

Open both the hot and cold water faucets above the bypass valve and wait till all the air has

been evacuated from the piping.
When the air is completely purge, the electric power supply can now be re-activate to the

water heater.
(Timer set-up)

The plastic cover can be remove by turning it counter clockwise.Turn the hour hand clockwise

to set it with the actual hour time.

When the little red knob is at the ‘O’ position, the pump is set off. When this red knob is slided

to the ‘I’ position, the pump is set operational. To use the timer to turn the pump on and off,

align the red knob to the line in the middle of the ‘O’ and ‘I’ position. You can now make your

selection between these 3 choices.
Use the timer to turn the pump on and off while required. For example, the system

can be on from 5:30am to 9:00am and from 4:30pm to 11:30pm. Each little sliding

switch around the timer is representing 15 minutes. To set this example, push

the slides out accordingly to the hour scale around the timer, as shown on the picture C.
Install the electric cord of the pump in a 3 prong electrical outlet. Make sure the electrical cord

is tied, so it doesn’t touch any hot water pipes that may damage same.

STEP 8

STEP 9

STEP 10

STEP 11

STEP 12

Picture C

FOR INFORMATION TEL: 514.337.4415 FAX: 514.337.4029

Advertising