REPAIR PARTS

Ref Pieces

Descriptions

1

310178

Complete motor

2

310179

Insulation sheet

3

310180

Rotor & impeller assembly

4

310181

Seal plate

5

310182

Pump ‘ O ‘ ring

6

310183

Pump housing

7

310184

Inlet ‘ O ‘ ring

8

310186

Inlet adaptor

9

310187

Inlet adaptor screws (4)

21

310177

Capacitor

22

310176

Timer

23

310175

Timer screws (4)

24

310174

Capacitor top cover

25

310173

Screws (2) (Capacotor case)

26

310172

Timer cover

31

310188

Thermostatic valve

32

310189

Threaded flex hose 3/8" X 1/2"

33

310190

Threaded flex hose 1/2" X 1/2"

Repair parts may be ordered from your autorized point of sale or from

BUR-CAM PUMPS

5

FOR INFORMATION TEL: 514.337.4415 FAX: 514.337.4029

300521 2011

1/2”

3/8”

1”

1/2”

1/2”

1”

08

07

01

02

03

04

05

06

22

21

23

24

25

26

32

33

31

09

Genie by-pass valve operation :

Trouble shooting

AFTER THE INSTALLATION, IF THERE IS NO HOT WATER AT THE HOT WATER

FAWCET OR IF THERE IS HOT WATER ON THE COLD WATER SIDE, PLEASE PROCEED WITH

THE FOLLOWING STEPS TO DETERMINE IF THE GENIE BY-PASS VALVE IS FULLY FUNCTIONAL.

A. Close the cold water supply valve under your sink.
B. Open the cold water fawcet to test the Genie by-pass valve.
C. The water should flow from the fawcet until hot water reaches the Genie by-pass

valve. Then, the flow should eventually decrease until no more water is flowing

from the cold water fawcet when the Genie by-pass valve is closed. If the Genie

by-pass valve does not close, you will have a mixture of cold and hot water.

Contact our customer service departement at 1.800.361.1820.