How to use the ez-watcher/magic tuner, Display of operating environment temperature – Elitegroup EZ-Buddie2 D21 I4-3 Install v.2 User Manual

Page 5

Advertising
background image

5

How to use the EZ-Watcher/Magic Tuner

When the PC is booting, EZ-Watcher starts at the simultaneously and conducts POST to show the POST results. In
addition, EZ-Watcher will simultaneously display the temperature status of the CPU and the temperature inside the PC
case along with the current operating speed of the CPU. EZ-Watcher will check the operating status of the CPU/mainboard,
memory, hard drive, and optical device drive one by one with each corresponding icon light up see Fig 2, 3, and 4. When
Fig 4 is shown on the monitor, it means everything goes well.







Fig 2 Mainboard Icon lights up Fig 3 Memory Icon lights up Fig 4 Hard Drive and Optical Device

Drive Icons light up

When any error is detected in the CPU/Mainboard, memory, or IDE device, the corresponding icon will start to blink and the
tool icon will also light up, as shown in Fig 5, 6, and 7, indicating the system needs some maintenance.







Fig 5 The CPU/mainboard may Fig 6 Hard Drive may Fig 7 Optical Device Drive may

need to be

repaired need to be repaired need to be repaired

We strongly suggest that you utilize the devices listed in our AVL (Approved vendor list) on the website. We’ll
regularly update the AVL. Once EZ-Watcher shows that the boot procedure cannot be completed, please look for
the nearby distributors for troubleshooting. Do not attempt to operate the PC by yourself. Any damage resulted
from your misuse and faulty operation will not be covered by the warranty.

Display of Operating Environment Temperature:

EZ-Watcher provides CPU monitoring function and the system operating temperatures right after PC successfully booting.
When only the last three green blocks of the temperature status icons are lit as in Fig 4, it indicates that the operating
temperature is in a normal state. If three yellow blocks are lit, it indicates that the operating temperature is slightly higher
than the normal state. Please refer to Fig 8. If the first three orange blocks are lit, it indicates that the working temperature
is abnormally high. Please refer to Fig 9. If the temperature continues to rise, the top Over Heat icon will be lit and start to
blink, indicating that the operating temperature is too high. Please refer to Fig 10.

Advertising