HATZ Diesel 2G40 H User Manual

Page 13

Advertising
background image

– As soon as the engine runs, release the start

key. It must return to position I by itself and
remain in this position during operation.
The battery charge telltale and oil pressure
warning must go out immediately after start-
ing. Indicator light „1“ is on when the engine
is in operation.

– The engine temperature display „4“ (additional

equipment) lights up if the temperature at the
cylinder head becomes too high.
Switch off the engine and trace and elimi-
nate the cause of the problem
, chapter 7.

– The air cleaner maintenance indicator „5“

(additional equipment) only lights up during
operation if the air cleaner element needs to
be cleaned or renewed (chapter 5.4.2.).

– Always turn the start key back to position 0

before re-starting the engine. The repeat lock
in the ignition lock prevents the starter motor
from engaging and possibly being damaged
while the engine is still running.

Important !
If a starter protection module is fitted, the key
must be turned back to position 0 for at least
8 seconds if the engine fails to start, before a
second attempt of starting can be made.

Note:
Start for max. 30 seconds. If the engine does
not run after this time, turn starter key back to
position 0 and eliminate the cause, Chapter 7.

Preheating device with automatic heating
timer
(additional equipment)

The preheating light „6“ lights up additionally at
temperatures below 0° Celsius (Fig. 12).

– After the light has gone out, start the engine

without delay.

Automatic shut-down function
(additional equipment)

This is characterized by a brief flashing of all
pilot lamps once the starter key has been turned
to position I (Fig. 12).

Important !
If the engine cuts out immediately after starting
or switches off by itself during operation, a mon-
itoring element in the automatic shutdown sys-
tem has tripped. The corresponding indicator
light (Fig. 12, positions 2 - 4) will come on. After
the engine has stopped, the display continues to
glow for about 2 minutes.
The electrical device then switches itself off au-
tomatically.
The display lights up again after the start key
has been turned back to position 0 and then to
position I again.
Trace and eliminate the cause of the
operating fault before trying to restart the
engine
(see chapter 7).
The display light goes out when the engine is
next started.

Even with automatic shutdown monitoring the
oil level must be checked every 8 – 15 operat-
ing hours
(chapter 5.2.1.).

12

Advertising
This manual is related to the following products: