Hired-Hand RollSeal Rolling Dampers User Manual

Page 2

Advertising
background image

RollSeal, INC.

• 1751 Co Road 68 • Bremen, Alabama 35033 • Phone 256-287-7000 • Fax 256-287-7010

Sheet No. 4801-0158 Rev 4-04

Page 2 of 5

Rolling Damper

Automatic

(Automatico)

Open
(Abierto)

PROT ECTED UNDER ONE OR MORE OF THE FOLLOWING
PATENTS 5,566,736 5,752,557 5,785,105 5,960,847 OR

OTHER PATENTS PENDING.

OPERATING INSTRUCTIONS

4501-5008

1. For normal operat ion, place

to

.

2. To open shutter for cleaning or
mantena nce, place
to

. To return to normal operation,

place

back to

.

Open/Auto

Switch

Automatic

Open/Auto Switch

Open

Open/Auto Switch

Automatic

R

When this controller is us ed in a life support he ating and ventilation

system where failure could result in loss or injury, the user shoul d provide

adequa te backup ventilation or accept the risk of s uch loss or injury.

ADVERTENCIA

Cuando este control se utiliz e en sistemas de vent ilacion y calefaccion

para seres vivientes d onde una falla pueda causar una perdida o dano, el

usuario debera tener sistemas de vent ilacio n altern os o acept ar el riesgo
de perdida o d anos.

R

R

7.47 in.

18.9 cm

6.43 in.

16.3 cm

5 in.

12.7 cm

Fan Housing

Fan Housing

3.5 in.

8.9 cm

7.5 in.

19.05 cm

2.

Rolling dampers must be positioned to provide space to
mount controller. Follow dimensions given below for
positioning rolling dampers.
If controller is mounted between rolling dampers,
position rolling dampers with a minimum of 12 in.
(30.5 cm) between fan housings.


















































Rolling Damper

Automatic

(Automatico)

Open
(Abierto)

PROT ECTED UNDER ONE OR MORE OF THE FOLLOWING
PATENTS 5,566,736 5,752,557 5,785,105 5,960,847 OR

OTHER PATENTS PENDING.

OPERATING INSTRUCTIONS

4501-5008

1. For normal operat ion, place

to

.

2. To open shutter for cleaning or
mantena nce, place
to

. To return to normal operation,

place

back to

.

Open/Auto

Switch

Automatic

Open/Auto Switch

Open

Open/Auto Switch

Automatic

R

When this controller is us ed in a life support he ating and ventilation

system where failure could result in loss or injury, the user shoul d provide

adequa te backup ventilation or accept the risk of s uch loss or injury.

ADVERTENCIA

Cuando este control se utiliz e en sistemas de vent ilacion y calefaccion

para seres vivientes d onde una falla pueda causar una perdida o dano, el

usuario debera tener sistemas de vent ilacio n altern os o acept ar el riesgo
de perdida o d anos.

R

R

Fan Housing

Fan Housing

8 in.

20.3 cm

12 in.

30.5 cm

NOTE: Maintain minimum distances
between fans as shown in these
diagrams.

3.

If controller is mounted above rolling dampers,
controller should be at least 5 in. (12.7 cm) from
rolling dampers. The rolling dampers should be
positioned with a minimum of 7.5 in. (19.1 cm)
between fan housings or 3.5 in. (8.9 cm) between
flanges of rolling dampers.

Advertising