4.

When mounting the RollSeal, the frame of the curtain should fit the opening of the fan as closely as possible to prevent blocking
air flow. When the openings are matched, level the top and the sides (leveling is very important, as the curtain may bind if not
leveled properly).




























5.

There are three pairs of holes pre-drilled down each
side of rolling damper flange as shown in diagram
below. For each pair of holes, select hole that lines up
better with support structure (fan or wall). Secure
flange of rolling damper to support structure with sheet
metal screws provided.

6.

There are two hinges at the top of the assembly, as
shown in Fig. 1. Each hinge has 4 pre-drilled holes.
Use lag bolts provided. Attach hinge to support
structure. Secure 2 of 4 holes on each hinge. At this
point, fan can be accessed by simply removing the
screws from the sides and lifting the entire frame on the
hinges.























NOTE: Shift bottom of rolling damper

right or left until both
diagonal measurements are
equal. At that point rolling
damper is square.

Level system

Hinge

Hinge

Screws

The two diagonals

must be equal.

This assures that the

RollSeal shutter Is

mounted SQUARE.

R

Secure hinge with
support screws.

Secure flange of rolling damper to support
with screw. Select screw hole that aligns
better with support.