Manual Part No. 4802-5084 rev 6-07 Page 2 of 4

PARTS LIST











TABLE A

INSTALLATION

The Base Bracket includes holes for mounting the assembly to a round or square column up to 4” Diameter with customer
supplied hardware. Refer to Figure 3 for Base Bracket hole sizes and spacing.

CAUTION

Do Not Use Lag Bolts To Secure The Wall Bracket To The Mounting Surface.
Lag Bolts May Turn Loose Over Time Due To Vibrations And Pressure.

















FIGURE 3

1. Mount the Base Bracket with customer supplied hardware. U-bolts or straight bolts can be used with the Base

Bracket. If straight bolts are used for mounting the bracket to a column, ensure the bolts are mounted completely thru
the column with washers on both sides of the column and nylon-insert lock-nuts for proper support. Ensure adequate
clearances are allowed in all directions for fan horizontal and tilt positioning.

DANGER

Do Not Install Orifice Fan Within Range Of Human Or Animal Contact!
The Post Mount Assembly Must Be Mounted To A Structurally Sound Column Or Mounting Surface!

Failure To Follow These Instructions May Result in Equipment Damage, Injury, Or Death!

!

!

Item #

Description Qty.

6403-4004 Base

Bracket

1

6403-4003 Arm

1

6403-4000

Swivel Sleeve Bracket, Right

1

6403-4001

Swivel Sleeve Bracket, Left

1

1004-7001

Screw, ½-13 x 2” Hx Hd

2

1001-1454 Nut,

Nylon-Insert,

½-13

2

1004-8006

Screw, ¼-20 x 1”, SS 2

Item #

Description Qty.

1001-0104 Nut,

Nylon-Insert,

¼-20,

SS 2

1004-2533

Bolt, ¼-20 x 1”

13

1001-1446 Nut,

Nylon-Insert,

¼-20

13

1003-5010

Washer, Flat, ¼” ID x ¾” OD

24

1004-1424

Bolt, 3/8-16 x 1-1/4”

2

1001-1456

Nut, Hex, 3/8-16

2

Base Bracket