Hired-Hand Funnel Flow Fans: 36 48 & 52 Funnel Flow Belt Drive Fan Unassembled User Manual

Page 10

Advertising
background image

Part No. 4801-5401 Rev 6/07

36" 48" & 52" Funnel Flow Fan – Unassembled

Page 10 of 12

Figure 22

Figure 23

Figure 24

Straight

Edge

should

touch

pulleys in

four

places.

6.22 Refer to Figure 22. Install the motor pulley with the set

screw facing outward. Install the shaft key (1019-2417)
into the pulley. Do not tighten at this time.


6.23 Install the belt as shown in Figure 22 and align the motor

pulley to the fan and idler pulleys by using a straight
edge as shown in Figures 23 and 24. Hold the straight
edge so that the edge touches the pulleys at four places.
Perform the alignment twice, once above the shaft level
as in Figure 23 and once below the shaft level as in
Figure 24.

6.24 Tighten the motor pulley set screw to 110 inch pounds

.

IMPORTRANT: Use Lock-Tite compound

.














6.25 Affix Labels. See Figure 25.




















6.26 Installation complete. (For Cone Installation, see Manual 4801-0163 FF Cone Installation)..

IMPORTANT!

Using a straightedge, align motor pulley with prop pulley as shown in Figures 23 and 24.

Figure 17 - Affix Labels

Warning Hand

(4501-1116)

Danger Hand

(4501-2622)

Danger Head
(4501-2620)

INSIDE

Product Label

(4501-0101)

Both Sides of

Orifice

Figure 25

Fan Rotary

Tensioner

(4501-6129)

48” and 52” Fan Brackets -Top View

Bearing

Maintenance

(4501-6128)

Bearing

Maintenance

(4501-6128)

36” Fan Brackets -Top View