Operation, Warning, Procedure at end of coil – Lincoln Electric IM677 RED-D-ARC LN-25 User Manual

Page 19: Welding warning

Advertising
background image

LN-25

B-8

B-8

ARC RAYS can burn.

• Do not touch metal por-

tions of the LN-25 lead
Clip when welding power
source is on.

OPERATION

CYLINDER may explode if
damaged.

• Keep cylinder upright and

chained to support.

• Keep cylinder away from

areas where it may be dam-
aged.

• Never lift welder with cylin-

der attached

• Never allow welding elec-

trode to touch cylinder.

• Keep cylinder away from

welding or other live electri-
cal circuits.

g. Be sure the proper contact tip for the wire size

being used is in the gun, and the gun is safe
from work contact. (Use the LN-25 insulated
gun holder.)

h. Turn on the welding power source, as well as the

shielding gas supply (if used).

• Unless an optional output control or

internal contactor is used, the
electrode is electrically “hot” when the
power source is on. The gun trigger
controls wire feed only.

a. Cut the electrode within approximately

3

8

” of the

end of the contact tip for solid wire and within
approximately

3

4

” of the extension guide for cored

wire.

b. Position electrode over joint. End of electrode

should be slightly off the work.

WARNING

WARNING

WARNING

OPEN ARC WELDING WITH A
CONSTANT CURRENT POWER
SOURCE

The LN-25 should be used with a constant current
machine only upon non-critical weldments and after
testing is done to assure quality is adequate for the

application.

PROCEDURE AT END OF COIL

When the wire on the reel is used up, the following
procedure is to be followed for removing the old wire
from the gun cable and loading a new reel.

a. Shut off power source if a Remote Output

Control Option or internal contactor is not used.

b.

Cut

the end of the electrode off at the gun end.

Do not break it off by hand since this puts a slight
bend in the wire and makes it difficult or
impossible to pull it back through the nozzle.

c. U n c o u p l e t h e g u n c o n d u c t o r c a b l e f r o m

the LN-25.

d. Lay the cable out straight.

e. Using pliers to grip the wire, pull it out of the

cable from the connector end. Do not pull it from
the gun end.

f. Put the conductor cable back on wire drive unit

after the electrode has been removed.

g. Load a new coil of wire and feed it through the

cable as described in Loading Electrode Section.

c. Lower welding helmet, close gun trigger, and

begin welding. Hold the gun so the contact tip to
work distance gives the correct electrical stick
out as required for the procedure being used.

NOTE:

If the arc voltage is not within the proper

procedure range adjust the power source output
control. (The CC mode WIRE SPEED setting should
not be changed from the preset procedure value for
the proper arc voltage.)

d. To stop welding, release the gun trigger and

then pull the gun away from the work. Store the
gun in the LN-25 insulated gun holder when
not welding.

WELDING