5 configuring and handling alarms, 1 configuring alarm input and linked actions, Configuring and handling alarms – LT Security PTZ217X12 User Manual User Manual

Page 40: Configuring alarm input and linked actions, Figure 3-25 self-diagnostics

Advertising
background image

User Manual of 4-inch High Speed Dome

31

panning loss, tilting loss and communication loss.

Note:

Panning loss and tilting loss refer to the failures of panning and tilting, for diagnosing the

electric motor of the speed dome.

DIAGNOSTICS

HIGH TEMP 0

HIGHEST TEMP 35°C

LOW TEMP 0

LOWEST TEMP 14°C

VIDEO LOSS 0

LOW VOLATE 0

POWER UP 0

BACK EXIT

DIAGNOSTICS

PAN LOST 0

TILT LOST 0

CAMERA LOST 0

BACK EXIT

Figure 3-25 Self-diagnostics

3.5 Configuring and Handling Alarms

3.5.1 Configuring Alarm Input and Linked Actions

Purpose:
This section explains how to configure the speed dome to respond to alarm events with alarm
linked actions, such as calling presets, patrols, patterns, scanning, etc.
Steps:
1. Move the cursor to enter the alarm configuration submenu:

MAIN MENUS > DOME SETTINGS > ALARMS > ALARM SETTING

ALARM

ALARM RESUME ON

ALARM SEQUENCE 5

ALARM REST DELAY 5

ALARM SETTING

BACK EXIT

ALARM SETTING

ALARM NUM 1

PRIORITY HIGH

ALARM ACT NONE

AUX NONE

ALARM INPUT OPEN

BACK EXIT

Figure 3-26 Alarm Configuration Menu

2. Choose the alarm number.

Steps:

(1) Move the cursor to ALARM NUM and click the IRIS+ to enter edit mode.
(2) Click the up and down direction buttons to select the number of the alarm which is to be

configured.

(3) Click IRIS+ again to confirm and exit edit mode of this column.