RIKON Power Tools 10-308 User Manual

Page 11

Advertising
background image

11

Adjustments

Guide Lock
Knob

Upper Guide

Blade Guard

Blade guard

Parts removed
to change blade

Changing Blade

Table bracket

Blade Changes

Over time blades can become dull and need to be
changed.

To change the blade you need to remove the sliding
table, the sliding rail next to the column and the corre-
sponding cover plate underneath.
 Move the upper guide post up from the sliding

table.

 Unscrew the 4 bolts that hold the table bracket on

to sliding table and remove.

 Remove the 2 cap screws that are used as table

stops from the sliding table.

 Carefully slide the table off the unit past the band-

saw blade and set aside.

 Remove the rear slide (one closest to column) and

the cover plate.

 Adjust lower bearing guides away from bandsaw

blade.

 Remove blade guard on column.
 Remove the blade guard which is attached to the

guide post.

 Take the tension out of the blade by loosening the

tension knob.

 Remove the blade from the upper and lower

wheels.

Blade Installation

To install a new blade reverse the above procedures
making sure the new bandsaw blade tracks true and all
components removed are adjusted properly and are
back in their proper place or setting. Please follow
bandsaw blade tensioning and tracking procedures.

Bandsaw blades are sharp take care in the installation
and removal process. Wear protective gloves if neces-
sary

Make sure the bandsaw is disconnected from the power
source before making any adjustments.

WARNING

!

Advertising