Troubleshooting – RIKON Power Tools 25-010 User Manual

Page 19

Advertising
background image

FOR YOUR OWN SAFETY, ALWAYS TURN OFF AND UNPLUG THE MACHINE BEFORE CARRYING OUT ANY

TROUBLESHOOTING.

For parts or technical questions contact: [email protected] or 877-884-5167.

WARNING!

Troubleshooting

19

Symptom

Possible Causes

Solutions

PLANER WILL NOT

FEED WORKPIECE

THROUGH

1. Planer drive belt worn / broken
2. Drive chain tension spring broken
3. Workpiece sticking on Planer body

4. Planer blades wrongly adjusted

1. Check and replace as necessary
2. Check and replace spring
3. Clean table and clean with silicone based

lubricant
4. Check and re-set blades

PLANER RISE AND

FALL IS STIFF OR

WILL NOT

OPERATE

1. Build up of shavings / dust on mecha-

nism
2. Rise and fall chain wrongly adjusted

or broken

1. Clean and lubricate with silicone based

lubricant
2. Have the machine checked and repaired

by a suitably qualified person / authorized

agent

NOT PLANING TO

UNIFORM

THICKNESS

1. Blades wrongly adjusted
2. Thicknesser table twisted as rise and

fall chain wrongly adjusted

1. Check and adjust blades
2. Have machine checked and repaired by a

suitably qualified person / authorized agent

NOT PLANING

WORKPIECE

SQUARELY

1. Blades wrongly adjusted
2. Fence not square to table
3. Outfeed table not square

1. Check and adjust blades
2. Adjust fence and 90° / 45° stops
3. Using a straight edge, align the outfeed

table to the infeed table

MACHINE WILL

NOT START

(GENERAL)

1. Blown fuse
2. Selector switch not set to correct

function
3. Micro switch(es) wrongly adjusted

1. Check / replace fuse
2. Check and reset switch as required

3. Check and re-adjust

MACHINE WILL

NOT START (JOINT-

ER

MODE)

1. Chip ejection hood not located cor-

rectly against micro switch

2. Out-feed table / locking lever not

located correctly against micro switch

3. Selector switch not set to correct

function

1. Check and refit chip ejection hood. En-

sure that planer table is raised to hold chip

ejection hood securely against micro switch
2. Check and refit out-feed table. Check that

right hand lock lever operates micro switch.

Adjust micro switch position if necessary
3. Check position of switch

MACHINE WILL

NOT START

(PLANER MODE)

1. Chip ejection hood not in correct

position / not operating micro switch
2. Selector switch not set to correct

function

1. Check position of hood and adjust as

necessary
2. Check position of switch

Advertising