Important flap valve servicing, Diaphragm servicing, Reassembly – SANDPIPER RHDF2 Hazardous Duty User Manual

Page 17: Pilot valve, Pilot valve actuator

Advertising
background image

rhdf2dl1sm_haz duty-rev0614

Model RHDF2 Hazardous Duty Page 15

Read these instructions

completely, before

installation and start-up.

It is the responsibility of

the purchaser to retain

this manual for reference. Failure to

comply with the recommendations stated

in this manual will damage the pump, and

void factory warranty.

IMPORTANT

FLAP VALVE SERVICING

Valve inspection requires removal of 3/8" hex nuts and elbows. When the top suction elbows are

removed, the valve and seat are connected as an assembly. When the bottom discharge elbows are

removed, the valve and seat stay with the outer chamber. Visual inspection and cleaning is possible. If

parts are to be replaced, remove the self-locking nuts and all parts are accessible.

DIAPHRAGM SERVICING

Diaphragms can be inspected or the diaphragm assembly removed without removing the suction and

discharge flanges. Remove (8) nuts around the chamber flange, and the housing assembly will pull

off. Flap valves can be inspected for proper seating at this point as well as the diaphragm. Use care to

keep foreign matter from behind the diaphragm. The opposite diaphragm may be inspected by the same

procedure. If either diaphragm has to be replaced, follow closely these steps: Pull the outer diameter

of one diaphragm off the (8) capscrews. NOTE: One side only! On the free diaphragm assembly, use

a 3/8" allen wrench to turn the assembly (diaphragm, plates and screw) loose from the shaft. Once the

assembly has turned, it will turn out by hand by use of the diaphragm. Now the opposite diaphragm

assembly and the drive shaft will pull free from the capscrews and pump intermediate assembly. The

interior components consisting of sleeve bearings, rod seals, and pilot valve actuator bushings are now

accessible for service if required. Hold the shaft in a clamping device making sure to protect surface of

shaft so as not to scratch or mar it in any way. The diaphragm assembly will turn loose. To disassemble

the components, turn a 1/4"-20 capscrew by hand into the tapped hole in the inner plate. This keeps the

plate from turning while the socket head capscrew is removed. To do this, place assembly in a vise so

the two protruding ends of screws are loose in the vise jaws (about 3/4" apart). Turn the center screw

loose from the back plate and the assembly will come apart.
“AirVantage CAUTION” – If product is observed on the air side of the diaphragm, refer to the “Air-

Vantage Servicing” section of the service manual.

REASSEMBLY

All procedures for reassembling the pump are the reverse of the previous

instructions with further instructions as shown:
1. The diaphragm assemblies are to be installed with the natural bulge outward or toward the head

of the center screw. Make sure both plates are installed with outer radii against the diaphragm. After

all components are in position in a vise and hand tight, set a torque wrench for 480 inch pounds (40 ft.

pounds) (54.23 Newton

meters) or, 600 inch pounds (50 ft. pounds) (67.79 Newton meters) for Santoprene, using a (3/8") allen

head socket. After each diaphragm sub assembly has been

completed, thread one assembly into the shaft (held near the middle in a vise having soft jaws to protect

the finish) making sure the stainless steel washer is in place on the capscrew.

Make sure 1/4"-20 mounting screw has been removed and that the bumper (Item #19 on drawing) is

in place in the shaft.

Install this sub assembly into the pump and secure by placing the outer chamber housing and

capscrews on the end with the diaphragm. This will hold the assembly in place while the opposite side is

installed. Make sure the last diaphragm assembly is torqued to 30 ft. lbs. (40.67 Newton meters) before

placing the outer diaphragm over the capscrews. If the holes in the diaphragm flange do not line up with

the holes in the chamber flange, turn the diaphragm assembly in the direction of tightening to align the

holes so that the capscrews can be inserted. This final torquing of the last diaphragm assembly will lock

the two diaphragm assemblies together. Place

remaining outer chamber on the open end and tighten down the securing nuts

gradually and evenly on both sides.

Caution should be used while reassembling Flap valves. The valves are designed for some preload

over the retainer hinge pad. This is done to insure proper face contact with the seat. After all parts are

in place, tighten the lock nuts down on the assembly to the point where visual inspection shows that

seat and valve face mate without gap. This is important for dry prime. However, after priming action has

started, valves will function due to differential pressure without concern or trouble.

PILOT VALVE

The pilot valve assembly is accessed by removing the main air distribution valve body from the

pump and lifting the pilot valve body out of the intermediate housing.

Most problems with the pilot valve can be corrected by replacing the o-rings. Always grease the

spool prior to inserting it into the sleeve. If the sleeve is removed from the body, reinsertion must be

at the chamfered side. Grease the o-rings to slide the sleeve into the valve body. Securely insert the

retaining ring around the sleeve. When reinserting the pilot valve, push both plungers (located inside the

intermediate bracket) out of the path of the pilot valve spool ends to avoid damage.

PILOT VALVE ACTUATOR

Bushings for the pilot valve actuators are threaded into the intermediate bracket from the outside.

The plunger may be removed for inspection or replacement. First remove the air distribution valve body

and the pilot valve body from the pump. The plungers can be located by looking into the intermediate. It

may be necessary to use a fine piece of wire to pull them out. The bushing can be turned out through the

inner chamber by removing the outer chamber assembly. Replace the bushings if pins

have bent.

Advertising