SANDPIPER RHDF2 Hazardous Duty User Manual

Page 19

Advertising
background image

rhdf2dl1sm_haz duty-rev0614

Model RHDF2 Hazardous Duty Page 17

INTERMEDIATE AND AirVantage SENSOR SERVICING

• To service the intermediate and AirVantage sensor, first shut off and bleed the air being supplied to the

pump. For safety purposes, the air supply line should be disconnected from the pump. Shut off both the

suction and discharge lines to the pump. Consult the “Composite Repair Parts Drawing”.

Step #1: Remove the Patch Cable

• Twist the ribbed portion of the patch cable connector in a counterclockwise direction, until it unthreads

from the connector. The cable can either be removed from the intermediate or from the control module.

Step #2: Remove the AirVantage from the Pump

• Use a ½” socket and remove the four 5/16-18 x 5 cap screws that hold the AirVantage to the pump. Be

sure to support the weight of the AirVantage while removing the last cap screw. After the AirVantage is

removed from the pump, set the unit down on the plastic cover located on the bottom.

Step #3: Remove the Manifolds, Chambers, and Diaphragms (See Diaphragm

Servicing Section)

Step #4: Remove the Diaphragm Assemblies

• Refer to the “Diaphragm Servicing” section of the manual to remove diaphragm assembly from the

pump.

• “AirVantage CAUTION” – When the diaphragm assembly is removed, watch for the brass probe

tips located on the end of the sensor rod. There is one brass probe tip and one o-ring per

side. Inspect the probe tips and o-rings for wear. For every diaphragm service, these parts should be

replaced and are available in kit form. Consult the “Composite Repair Parts Drawing” for part numbers

and quantities.

Step #5: Remove the End Caps

• Use an Allen wrench and remove the two screws from the End Caps on either side of the intermediate.

• Use two small flat-head screw drivers to simultaneously pry the End Caps up at the ends.

• “AirVantage CAUTION” – Remove the End Caps from the intermediate with caution, taking care

not to damage the sensor. Inspect the gaskets and u-cup seals under each End Cap and replace

them as necessary.

Step #6: Accessing the Actuator Plunger Bushings and O-rings

• The actuator plunger pin bushings and o-rings can now be accessed. If it is determined that these parts

need to be replaced, use a small screwdriver and remove the retaining rings.

• NOTE: It is recommended that new retaining rings be installed after disassembly. The bushing

and o-ring can now be removed and inspected.

Step #7: Accessing the AirVantage Sensor

• If the sensor needs to be replaced, use a 13/16” socket and remove the plastic nut securing the

connector to the intermediate. Slide the connector out of the hole, taking care not to lose/misplace the

gasket on the connector.

• The sensor can now be removed from the intermediate assembly.

Step#8: Reinstallation

• Slide the new sensor assembly in the intermediate.

• “AirVantage CAUTION” – Make sure the cable assembly fits into the groove machined in the

intermediate. Failure to do so may damage the cable during assembly.

• Feed the connector through the hole in the intermediate, making sure the gasket is on the connector

before installation. The flat edge on the connector should line up with the inside of the intermediate.

Install the nut and hand tighten it using a 13/16" socket.

• The inner chambers and gaskets can now be reinstalled. Use blue thread locker on the inner chamber

bolts and torque them to 300 in-lbs.

• Refer to the “Diaphragm Servicing” section of the manual to finish the diaphragm installation procedure.

Page 17

PROBE TIP

O-RING

SENSOR, FEED BACK

WASHER, SEALING

PLATE, DIAPHRAGM

DIAPHRAGM

PAD, WEAR

PLATE,

OUTER DIAPHRAGM

CAPSCREW

SENSOR COVER

CAPSCREW

END CAP

FEED BACK SENSOR

O-RING

CAPSCREW

INTERMEDIATE

JAM NUT

O-RING

FOAM BUMPER

BEARING

SEAL

Note: Refer to Composite Repair Parts

List on page 12 for part numbers

A

BRACKET, INTERMEDIATE, ASSEMBLY

SENSOR, FEEDBACK

NUT

SEAL

DIAPHRAGM

PLATE,

OUTER DIAPHRAGM

PLATE,

INNER DIAPHRAGM

PROBE TIP

O-RING

SENSOR, FEEDBACK

BUMPER

DETAIL A

FLAT EDGE

Advertising