Rush power m, 3 line voltage and protective functions, 4 safety standards – SHARKOON Rush Power M User Manual

Page 5: 2 temperature range and humidity

Advertising
background image

2.3 Line voltage and protective functions

This PSU works with 100 to 240 V (50/60 Hz) and is equipped with the following

protective functions:

1. Over voltage protection:

The power supply provides a latch mode against over voltage, as defined below:

Min.

Max.

Unit

+5 V

5.74

7.5

Volt

+3.3 V

3.76

4.8

Volt

+12 V

1, 2

13.4

17

Volt


2. Short circuit protection:

The power supply is designed with a short circuit protection to prevent damage

of the power supply components. Main power will be shutdown when a short

circuit occurs. The PSU will return to normal after the short circuit has been re-

moved and the main power switch has been turned off and back on again, with a

minimum cycle pause of 2 seconds.

3. Over current protection:

The power supply provides a latch mode against over current, as defined below:

Model No.

Limit value (min.)

Limit value (max.)

Unit

+12 V

1, 2

SHA-R400M
SHA-R500M
SHA-R600M

23
23
31

36
37
50

A

2.4 Safety standards

Our power supply has been certified to comply with CB, FCC, BSMI and CE safety

regulations.

Operation

0 to +40 °C

20 – 85% rel. humidity,
non-condensing

Storage

-40 to +70 °C

5 – 90% rel. humidity,
non-condensing

2.2 Temperature range and humidity