Environmental:

• Storage temperature range: -40 to +70°C (-40 to +158°F)

• Operating temperature range: -30 to +65°C (-22 to

+149°F (1)

• IP67 waterproof (according to IEC529 standard)

• Vibrations and shocks: ETS300-019

• Withstands 2-meter fall on concrete.

DC Power Input:

• Range: 9 to 16 V (12 V typical, 1 A)

• Protected from polarity reversal and transient voltage

(according to ISO7637 standard)

Built-in Batteries:

• Specifications:

– Two non-removable cells

– Type: Lithium-ion (Li-Ion), re-chargeable, 5 Ah, 3.7 V

– Life time: 10 hours at +20°C (+68°F) or higher, 8½

hours at 0°C (+32°F), 6 hours at - 20°C (-4°F)

– Protected from over-voltages, under-voltages, over-

currents

• Charging times (typical):

– Standard: 7 to 8 hours

– Fast: 3 hours approximately

• Battery charger: Use exclusively the universal AC/DC

adapter provided to charge the ProMark 700 batteries:

– 100-240 V AC input, 50-60 Hz, 0.6 A

– 12 V DC output, 2.08 A

• Battery charging temperature range: 0° to +40°C (32° to

104°F); altitude max.: 2,000 m (6,562 feet)

Certifications:

• CE marking according to R&TTE European directives

• FCC (USA) and IC (Canada)

1. Can start instantly at -20°C (-4°F) without warm-up time. Can be started at -30°C (-22°F) but will become