Repetition Shots

The Repetition shots function allows you to perform sideshots or traverse shots
using any number (between 1 and 99) of repeated measurements (“Sets”).

Go to the

Survey menu and tap Repetition Shots.

Tap

in the command bar to access the job settings relating to repetition

shots (equivalent to navigating to the

Job > Settings > Repetition tab).

Tap the

Repetition tab. The Rep Shoot Sequence field allows you to choose the

desired sequence of repetitions (7 available):

– “FS” stands for “Foresight”:

– “BS” stands for “Backsight”

– The ">" symbol is used to denote the next shot coming in the sequence

using the same face of the instrument (direct or reverse).

– The "^" symbol is used to denote when in the sequence you will flip the

instrument to take observations in the opposite face.

The other parameters on this screen are self-explanatory. Set them to meet
your application. The

Radial Sideshot Seq field allows you to specify the

sequence of observations to be taken in the Radial Side Shot routine. This
setting is NOT used for either regular repetition shots or multiple side
shots.

Tap

to return to the

Repetition Shots window.

Use the

Foresight field to enter a name for the point you will measure

through repetition shots.

Enter the number of Sets you want the sequence to be repeated.

Select the type and enter the height (

HR) of the target used on the foresight

point.

Start the sequence by tapping either

HA, ZA, SD or All, whichever is

appropriate in your case. Depending on the instrument used, run the series
of measurements manually or let the instrument do this automatically.
Results are displayed at the end of the sequence (see illustrated).

Average of: Shows the average angle or distance to the point from all the
shots taken. The number in parenthesis is the total number of
repetitions performed.

Worst Residual: Displays the worst residual calculated from all the sets
of the selected measurement type.

You may use one or more of the

Toss buttons to remove from the solution

the set of measurements that provided the worst residual. A

Toss button

can only be used if three or more sets have been collected.

When you tap

HA, ZA, SD or All, Survey Pro will collect an additional

observation of that type (or all of them) and add it to the sets already
collected.