Spectra Precision Survey Pro v5.1 User Manual

Page 47

Advertising
background image

41

NOTE: You can tap the

Wait xx button to accept the point before the minimum

duration has expired. You will in return be informed that the minimum duration is
not yet met, at which point you can discard the warning by tapping

Accept anyway.

Average for cleared: Screen type [2] will be displayed for an unlimited
period of time, until you tap

Accept. Point collection is then complete,

unless some other acceptance criteria are not met in which case you will
see screen type [3] after you tap

Accept. You can also choose to accept the

point before the wait time expires.

Automatically accept when criteria is met checked: The use of this parameter
makes sense when it is combined with

Average for checked. Survey Pro will

automatically store the point at the end of the averaging time, unless some
other acceptance criteria are not met. In that case, at the end of the count
down, the

Accept button will be restored on the screen and when you tap

on it, you will see screen type [3].

When screen type [3] is displayed, you can either ignore the warning message
(tap

Accept Anyway), or ask for more data collection on the point (tap Keep

Measuring) until you are satisfied with the collected data (you will then tap
Accept to end the point collection).

[1]

[3]

[2]

Advertising