Stakeout routines – Spectra Precision Survey Pro v5.1 User Manual

Page 56

Advertising
background image

50

7. Stakeout Routines

This section introduces the basic stakeout routines with optical and GNSS
instruments. When you become familiar with these routines, you will be able
to extend your knowledge on more specific stakeout routines, such as stake to
line, slope staking, etc.

What you should have done already:

You should have now completed the station setup with your optical
instrument.

You should have now solved the calibration with your GNSS receiver.

If the points to stake are not in your job, you can use the

File > Import

function to import your points to the job (see Importing Data on page 12).

Staking Points With a

Mechanical Optical

Instrument

Go to the

Stakeout menu and tap Stake Points.

Use the

Design Point field to enter the name of the first point you want to

stake.

Enter an integer in

Increment. This will allow Survey Pro to automatically

select the next design point to stake once the current one will have been
staked.

e.g. “ST101” first staked and Increment= 2, then next point will be “ST103”.

(Tapping the

Next Point button will instantly select the next point from the

list, based on the

Increment value.)

Choose the type of target used and set the height of the rod (

HR field). The

information underneath describes the current station setup.

(You may use the

Backsight button to check the station setup or start a new

setup.)

Tap

Solve. The Stake Points screen now indicates the angle and distances

the instrument should measure with the target placed exactly over the
design point.

It may be convenient at this point to change the circle setting so that it
reads zero when the total station is facing toward the design point. This can
be done by tapping the

Circle Zero button. The first time you tap this button

during a stakeout session, a message will warn that the original backsight
reference will be lost.

Advertising