Star Water Systems EL10S User Manual

Page 12

Advertising
background image

12

PUMP ELECTRICAL CONNECTIONS (CONTINUED)

3. Insert an electrical wire strain relief into the

opening in the side of the pressure switch

closest to the motor. (

Fig. 3)

IL1372

3

IL1373

Wire from

motor

4

IL1374

Wire from

motor

5

IL1375

Wire from

motor

Ground Screws

6

6. Connect the green ground wire from the

motor cable to one of the green ground

screws at the bottom of the pressure switch.

(

Fig. 6)

5. Connect the two motor wires of the motor

cable to the two inside terminals on the

pressure switch. (

Fig. 5)

4. Thread the cable from the pump motor

through the strain relief into the pressure

switch cavity and tighten both screws on the

strain relief. Do not crush wire. (

Fig. 4)

Advertising
This manual is related to the following products: