8. All piping from the well to the pump should

slope slightly upward with no sagging. Support

suction pipe between water source and pump.

Unions in the suction line near the pump and

well will aid in servicing. Be sure to leave

enough room so that wrenches can be used

easily.

(

Fig. 8)

NOTE: Look for leaks or a milky color in the

discharged water, which indicates an air leak.

Re-prime if necessary, following steps 1 through

6 above. Reset breaker at the breaker box. All

connections must be water and air tight in order

for pump to operate.

questions? Call 1-800-742-5044 Monday -

Friday 7:30 am - 5:00 pm EST.

IMPORTANT: If the pump fails to prime within five minutes:

Turn power off at the breaker box and check all pipe connections for leaks. All connections must be

water and air tight in order for pump to operate.

PUMP PRIMING & STARTUP (CONTINUED)