Do not use detergent in unit, Operating procedures, Warning – Triangle Engineering of Arkansas AQ3613 User Manual

Page 4: Maintenance

Advertising
background image

OPERATING PROCEDURES

1.

Connect standard size water hose to water supply.

2. Connect water hose to 3/4 inch adaptor on unit and allow reservoir to fill to
capacity. Water flow will automatically shut off at proper level.
3. Align splash guard (curved semicircular pipe located above spray bar).
4. The spray bar should distribute water flow in an upward vertical direction. To
adjust the spray bar, gently turn until the bar is angled upward 2-6 degrees facing
intake side of cooling pads. In the correct position, the splash guard and spray bar are
designed to provide maximum water coverage over the cooling pad surface.
5.

Turn on pump switch and allow to run for 2-3 minutes.

6.

Turn on fan switch to begin air circulation.

7. When not in use, turn off pump and fan switches, then drain water from reservoir.

Splash guard

Spray Bar

AIRFLOW

ALWAYS disconnect unit
from electrical source prior to
performing maintenance.

WARNING:

Use of Heavy Duty electrical cord (no lighter than 12/3) and
shorter than 25 feet is advised.

DO NOT USE DETERGENT IN UNIT!

MAINTENANCE