WEN 56475 4750W Electric Start User Manual

Page 18

Advertising
background image

15

Electric Start

To start the generator using the electric start function, perform the following steps:

1. Make sure no electrical devices are connected to the generator. Such devices can make it

difficult for the engine to start.

2. Check that the generator is properly grounded (see Figure11, “Ground the Generator”).
3. Check the oil and gas levels.
4. Turn the fuel valve to the “ON” position (see figure 12).
5. Move the choke lever to the “Start” position (see figure 13).
6. Set the engine switch to the “ON” position.
7. Press the engine switch to the “START” position for 2-3 seconds or until the engine starts.

NOTE: If the engine does not start after 2-3 seconds, release the switch from the start position.
Keeping the switch in the START position too long can damage the starter.

8. If engine fails to start, wait 10 seconds, then repeat step 7. NOTE: After repeated attempts to

start the engine, please consult the troubleshooting guide before attempting again. If problems
persist please call (800) 232-1195 M-F 8-5 CST.

9. Once the engine has started. Slowly move the choke lever all the way to the “Run” position.
Allow the generator to run for several minutes before attempting to connect any electrical devices.

Figure 12- Fuel Valve in the “on” position

Figure 13- Pull choke out for closed position.

Push in for open position.