SOME NOTES ABOUT POWER CORDS

Long or thin cords can drain the power provided to an electrical device by the generator. When
using such cords, allow for a slightly higher rated wattage requirement by the electrical device.
See Figure 18 for recommended cords based on the power requirement of the electrical device.



Device Requirements

Max. Cord Length (ft) by Wire Gauge

Amps

Watts (120V)

Watts (240 V)

#8 wire #10 wire #12 wire #14 wire #16 wire

2.5

300

600

NR

1000

600

375

250

5

600

1200

NR

500

300

200

125

7.5

900

1800

NR

350

200

125

100

10

1200

2400

NR

250

150

100

50

15

1800

3600

NR

150

100

65

NR

20

2400

4800

175

125

75

50

NR

25

3000

6000

150

100

60

NR

NR

30

3600

7200

125

65

NR

NR

NR

40

4800

9600

90

NR

NR

NR

NR

*NR= not recommended

Figure 18- Maximum Extension Cord Lengths by Power Requirement

STOPPING THE GENERATOR

To stop the generator:

1. Turn off all electrical devices prior to unplugging them from the generator. Unplugging

running devices can cause damage to the generator.

2. Turn the engine switch to the “OFF” position.
3. Turn the fuel valve to the “OFF” (horizontal) position.

WARNING:

Allow the generator to cool for several minutes before touching

areas that become hot during use.

CAUTION: Allowing gas to sit in the generator tank for long periods of time without use can
make it difficult to start the generator in the future. Never store generator for extended
periods of time with fuel in the tank.