7

Motor

Be sure your power supply agrees with nameplate marking. 110 Volts AC

only means your tool will operate on standard 60 Hz household power. Do not

operate AC tools on DC. A rating of 110 volts AC/DC means that your tool

will operate on standard 60 Hz AC or DC power. This information is printed on

the nameplate. Lower voltage will cause loss of power and can result in over-

heating.

Extension Cords

When using an extension cord, be sure to use one heavy enough to carry the

current your product will draw. An undersized cord will cause a drop in line

voltage resulting in loss of power and overheating. The following table shows

the correct size to use depending on cord length and nameplate ampere rating. If

in doubt, use the next heavier gage. The smaller the gage number, the heavier the

cord.

SAVE THESE INSTRUCTIONS

Minimum Gauge for Cord Sets

Volt

Total Length of Cord in Feet

120V

0 - 25

(0-7.6 m)

26 - 50

(7.6-15.2 m)

51 - 100

(15.2-30.4 m)

101 - 150

(30.4-45.7 m)

230V

0 - 50

(0-15.2 m)

51-100

(15.2-30.4 m)

101-200

(30.4-60.9 m)

201-300

(60.9-91.4 m)

Ampere Rating

American Wire Gauge

More Than

Not More

Than

0

6

18

16

16

14

6

10

18

16

14

12

10

12

16

16

14

12

12

16

14

12

Not Recommended

Intended Uses:

• Grinding, Sharpening and Honing applications on knives and tools.
• Light duty grinding in metal.
• Only for use with consumer applications.
• Tool should only be used with sharpening cassette installed.

Unintended Uses:

• Industrial or commercial grinding or sharpening applications.
• Extended, continuous heavy duty use.