Aquametrix SLT-5 Ultrasonic Flow & Level Monitor User Manual

Page 3

Advertising
background image

Simple Installation and Calibratio

n

Mount the SLT-5U non-contacting ultrasonic sensor at the top of a tank to con-

tinuously monitor level. The Sensor self-tunes to extended cable lengths so

the electronics enclosure/display can be mounted at a convenient location.

Select LEVEL or RANGE mode

It is fast and easy through the SLT-5 calibration menu. Simply follow the menu

prompts and set up the SLT-5 to display

level in your choice of measurement

units (ft, cm, gallons, liters, percent etc.)

for vertical and horizontal round tanks.

Advanced Operating System

You can control the SLT-5s response

to conditions like turbulence or splash-

ing and to reject tank agitators. The

SLT-5 automatically adjusts itself to

obtain the best signal. False echoes

are suppressed and filtered to ac-

curately display the correct level.

Pump Control and Alarms

Program separate ON and OFF

set-points for the SLT-5’s 3 built-

in control relays. Use them for pump control, pump alternation, high or low

level alarms, air temperature alarms, automated valves or annunciators.

Isolated 4-20mA Output

Ready for direct connection to PLC’s or comput-

ers and rated for 1000 ohm resistive load. Pro-

grammable offsets allow 4 and 20mA to be offset

from the instrument calibration for special control

applications.

Select FLOW mode for Open Channel applica-

tions

Calibration is easy with Menu selection of

common flumes including Parshall, Palmer

Bowlus and Leopold Lagco, and Weirs in-

cluding V-Notch and Rectangular.

Displays, Totalizes, Transmits and Control

s

The SLT-5 large digital display shows the

flow rate while the 16-digit display shows

flow total. Use the SLT-5 isolated 4-20

mA output to transmit to chart record-

ers, and program the built in control relays

for flow proportionate control (for sam-

plers, chlorinators or external totalizers), and for flow/level alarms.

No Contact Sensor = No Maintenance

The SLT-5 Sensor mounts over the flume or weir, so there is no sen-

sor fouling or maintenance required. With built-in temperature com-

pensation, the SLT-5 maintains high accuracy (+0.25% of full

scale) to meet environmental monitoring requirements.

Includes Software for Custom Calibration

Run this software on your PC to determine the calibra-

tion formula for custom flumes, weirs or open channels then en-

ter the values into the SLT-5 calibration menu.

Tank Inventory and Pump Control

• Displays Continuous Level
• Controls Pumps and Alarms
• Transmits 4-20mA

Open Channel Flow Monitoring

• Works with any Flume or Weir
• Built-in Totalizer
• Password protect-

ed Calibration

Level

Flow

Model SLT-5 Non-Contacting Level & Flow Monitor

www.WaterAnalytics.net

978-749-9949