Operating instructions

US

4.2 Starting

Check that the oil level in the oil reservoir(s) (2) is between the MIN. and MAX. markings. The inlet water
shut-off cock should be open.
NOTE: The system automatically stops after approx. 4 seconds if there is no water consumption. In the
event of a power failure or activation of the thermal switch (with subsequent cooling) the system can be
restarted from pos. 0.

Check oil level
Turn to „Start“ position

KSA-1:

Turn the red start/stop knob (1) to position „Start“ (it’s spring-loaded and when released, it will

return to
position 1 = operation). Watch the pressure gauge (3) to see that pressure is being built up in the system
when activating the trigger of the spray handle, on which a spray lance set for high pressure is attached. If
pressure does not build, vent the machine as described in section 3.4 Venting.

Check oil level

Turn to:
Position 1

=

Pump no. 1 in operation

Position 2

=

Pump no. 2 in operation

Position 1+2 =

Pumps no. 1 & 2 in

operation

KSA-2:

Turn the red start/stop knob (1) to position 1, 2 or 1+2.

Ensure that pressure is building in the system by watching the pressure gauge (3). If pressure is not being
built, vent the machine as described in section 3.4 Venting.

4.3 Operation - automatic start/stop

Always hold the spray lance with both
hands!

Always lock the trigger when the machine
is not in operation.

Once started, the system will automatically re-start when the spray handle trigger (1) is activated. When
the trigger is released, the system automatically stops after approx. 4 seconds.
When the machine is not in use, the trigger should be locked by turning the safety knob (2) into position 0.