7.0 Troubleshooting and correction

US

You have chosen the best quality and therefore deserve the best service. To avoid unnecessary disap-
pointments, you should check the following before contacting the nearest ALTO service organisation:

Fault

Cause

Correction

Machine will not start

A fuse has blown

Change the fuse

Power/plug not connected

Connect power/plug

Thermal switch in motor

Let the motor cool. Start the machine and

activated

check that the working pressure is
not too high and that the mains voltage
corresponds to the specifications.

KSA-2 Thermal switch in water tank Let the water cool and check that the inlet

water temp does not exceed 160°F.

Machine stops shortly

Wrong supply voltage

Check that the supply voltage corresponds

after the start

to the specifications on the model tag
(see section 1.1).

Air in the system

Vent the system (see section 3.4).

Fuses blow

Supply is inadequate

Correct the installation so it corresponds to

for the ampere

the ampere consumption of the machine

consumption of the machine

at a minimum. Change fuse.

Working pressure

KSA-1 Nozzle partly clogged

Clear nozzle (see section 6.4)

too high

Working pressure too low

High pressure cock by outlet Close all high pressure cocks not in use.
point not completely closed

KSA-1 Water regulation valve not

Completely open the water regulation valve.

set at max pressure

Turn in the direction of the indicator.

KSA-2 Wrong MULTIPRESSURE

Check whether the total water volume of the

spray lance

spray lances in use exceeds the capacity of
the system. If necessary, change to other
spray lances.

Pressure fluctuating

High pressure hoses too

Detach high pressure extension hoses and

long

(machine vibrates) retry. Extension hose
max. 160 ft. Avoid long extension hoses
with many couplings.

Air in the system

Vent the system (see section 3.4)

Water inlet screen clogged

Clean the screen (see section 6.3)

No working pressure

Nozzle clogged

Clear the nozzle (see sec. 6.4)

No inlet water

Check that the shut-off cock of the water
supply is open. Check that the water supply
is adequate (see section 1.2).

High pressure cock of

Close all high pressure cocks not in use.

outlet point is open

Water volume too

KSA-1 Water regulation valve not

Open water regulation valve completely.

low

set properly

Turn completely open in the direction of the
indicator.

KSA-2 Nozzle partly blocked

Clear the nozzle (see section 6.4).

Should other malfunctions occur than those mentioned above, please contact your authorized ALTO
servicing distributor.

Customer services (US only):

ALTO U.S. Inc.

Phone: 877-322-2586 (Tech Support)

1500 N. Belcher Rd
Clearwater, FL 33765

Advertising