Operating instructions, High pressure mode, Low pressure mode – Alto-Shaam 52C3KSA -2 User Manual

Page 13: Regulation of pressure/water volume

Advertising
background image

13

Operating instructions

US

4.4 Double spray lance, regulation of pressure and water volume - KSA-1

Turn spray lance pressure reducing valve
(1):

Clockwise (B): high pressure

Counter clockwise (A): low pressure/
detergent application

The spray lance employs a high pressure nozzle and a low pressure nozzle.
On KSA-1 pump systems the water volume is adjusted on the water regulation valve of the pump (2).

High pressure mode

The max. working pressure of the machine is reached when the pressure reducing valve (1) is completely
closed (B), and the water regulation valve (2) is fully counter-clockwise. In this position only the high pres-
sure nozzle is used - high pressure mode. The water volume is infinitely variable (2) between min. and
max. output. Reduced water volume = reduced pressure. With the trigger released, turn the water regu-
lation valve (2) to adjust volume and pressure (clockwise = Lower volume and pressure). Minimum volume
results in a working pressure of 580 psi through the high pressure nozzle (only), and a water volume of
approx. 2.4 gpm. If you want more water volume, the valve (2) should be turned counter-clockwise until
the desired result is achieved. 1 turn provides change of approx. 725 psi.

Low pressure mode

When the reducing valve (1) is completely opened (A), the pressure will be fully reduced. The nozzle
pressure will be approx. 60 psi. In this position both spray nozzles are used - low pressure mode / possi-
bility of dosing detergents.

4.5 Double spray lance, regulation of pressure - KSA-2

Turn pressure reducing valve:

Clockwise (B): high pressure

Counter clockwise (A): low pressure/
addition of detergents

The spray lance features a high pressure nozzle and a low pressure nozzle. When the pressure reducing
valve (1) is completely closed (B) only the high pressure nozzle is used - high pressure mode. When the
reducing valve is open, (A) both nozzles are used - low pressure mode/applying detergents. The pressure
may be regulated between these positions.

Regulation of pressure/water volume

When using special COLORED spray lances, the pressure and the water volume may be chosen for the
individual cleaning task. The table shows the pressure (P) of the nine different nozzles, the water volume
(Q), the color code (C) and the number of pumps (N) required to support operation of the individual lan-
ces. Contact your ALTO distributor for further information.

MULTIPRESSURE

P

PSI

Q

GPM

C

N

390

3.7

White

1

390

7.7

Black

2

720

3.7

Brown

1

770

7.3

Green

2

1160

3.7

Blue

1

1160

5.9

Red

2

1550

3.7

Orange

1

1550

5.7

Yellow

2

2200

3.7

Steel

1

Advertising