19

BATCH TOTAL Display Mode


The BATCH TOTAL displays the JOB A total and the S1 & S2 total limit activation levels.
When the RT-Ex15 is programmed for BATCH TOTAL operation, both limits are assigned as
TOTAL A limits based on the KFT, decimal point, and engineering units. The TOTAL limit
activation levels are displayed unless assigned to another function. If so, the S1 or S2 display
would read as XXXX to indicate that it is not assigned to JOB A TOTAL function. A typical
display would be:




BATCH TOTAL Programming

The BATCH TOTAL program mode is used to quickly dedicate both limits as total limits and
program the values at which the limits (labeled S1 & S2) will activate. The BATCH TOTAL
display must be viewed to program the BATCH TOTAL limits. Use the MODE/DN button or
magnetic switch to select the BATCH TOTAL display. Press and hold the ENT button or
maintain the ENT magnetic switch. The display will first show a P in the lower left-hand corner
and will then highlight the first limit assignment S1 indicated with a blinking cursor. Entering a
value will assign the limit as a total limit based on the KFT, decimal location and KFT
engineering units. Select the digit to edit using the SEL button or magnetic switch. Use the UP
or DN button or magnetic switch to increment or decrement the variable value. When the
desired value is displayed, use the ENT button or magnetic switch to store the programmed value
and move the cursor to S2. Select the digit to edit using the SEL button or magnetic switch. Use
the UP or DN button or magnetic switch to increment or decrement the variable value. When the
desired value is displayed, use the ENT button or magnetic switch to store the programmed value
and exit the BATCH TOTAL program mode.

If either limit has been previously assigned to a function other than TOTAL A, the RT-Ex15 will
respond by asking “Limit mode different, want to change it?” Use the SEL button or magnetic
switch to toggle a “N” or “Y” response and use the ENT button or magnetic switch to answer. A
“Y” response will reset any previous limit assignment to Total A and zero the limit value. A “N”
response will leave the limit assigned to the previous function and the S1 or S2 display will read
as XXXX to indicate that it has no function in this mode.