LLC-BA Batch Unit

Operation and Programming Manual

20


AW Gear Meters

Originally Programmed Values

DELAY

00000.50

PRECUT

0000000.

BATCH 1

100.00

GATE TIME

0000001.

BATCH 2

000.00

0-set mA’s

000x.xx

BATCH 3

000.00

KFR RATE

00100.00

BATCH 4

000.00

DP KFR

00000.00

BATCH 5

500.00

ENG UNITS

hz

BATCH 6

000.00

KFT TOTAL

0010000.

BATCH 7

000.00

DP KFT

00000000.

BATCH 8

000.00

ENG UNITS

pul

BATCH 9

900.00

SER NR >

example

MODEL LLC - BA

AW Gear Meters

8809 Industrial Dr.

262-884-9800
Franksville, WI 53126

Programming the LLC-BA

The LLC-BA user will need to edit the default
Batch quantities as well as the default
application- dependant variables shown in the
Programming Label Diagram.

The KFR and KFT scaling variables shown
underlined in the Label Diagram at the right are
the default values, which display the rate in
Hertz and the totals in pulses. If the values
differ from the underlined variables, the AW
Gear Meter factory may have already
programmed the device for the K-factor in the
requested engineering units.

If the values on the LLC-BA label are the same as the underlined defaults shown here, the KFT and KFR
scaling variables require editing to display the required engineering units. See Entering/Editing the
Variables below for directions.

Program Mode

Use Program Mode to enter, edit, or examine variables and batch quantities.

You must enter variables before batch programming.

The PROGRAM/RUN input must be open (TERM 4 not connected to TERM 2) to enter the PROGRAM
mode.

Entering/Editing Variables

To enter Program Mode:

1. Press and hold the PROG key (ENT). The display will start flashing PROGRAMMING ????.
2. When the display stops flashing, release the PROG key (ENT)

The LLC-BA now displays the first variable, DELAY, and is ready for you to enter, edit or examine the
variables. After you have viewed/edited and stored each variable, the LLC-BA advances to the next
variable.

The factory default value follows the instructions below.