7. CERTIFICATION

Page 44 of 44

1. ATEX CERTIFICATE

2. US/CANADIAN CERTIFICATE

This product has been examined against the following standards

ATEX:

EN 60079-0:2009

EN 60079-2:2007

EN 60079-11:2007

EN 60529 (+A1):2000

US/CANADA:

FM3600 1998

FM3610 2010

FM3810 2005

FM3620: 2000

ANSI/NEMA 250: 1991

ANSI/IEC 60529: 2004

ANSI/NFPA-496: 2003

CSA-C22.2 No. 0.4: 1999

CSA-C22.2 No. 157: 2006

CSA-C22.2 No. 1010.1: 2004

CSA-C22.2 No. 60529: 2005

TYPE/MODEL

HAZARDOUS AREA PROTECTION DEGREE

CATEGORY

CERTIFICATE

SERIAL No.

POWER SUPPLY

Um:

PURGED ENCLOSURE VOLUME

MINIMUM PRE PURGE VOLUME

MINIMUM PURGE DURATION

MAXIUM ENCLOSURE LEAKAGE RATE

MINIMUM PURGE SUPPLY PRESSURE

MINIMUM PRE PURGE FLOW

MINIMUM FLOW DURING OPERATION

MIN. OVERPRESSURE DURING OPERATION

MAX. OVERPRESSURE DURING OPERATION

MAXIMUM PROCESS GAS FLOW

MAXIMUM PROCESS GAS PRESSURE

Flammable substance oxygen concentration must not exceed 2%.

Flammable substance shall not have a UEL higher than 80%.

: WIM 9610

: CLASS I, DIV2, GROUPS B, C & D

: TYPE Z - PURGE

: T3C, TA = +5C TO +45C

TYPE 4X (US), IP66

: XXXX

: 115Vac, 60Hz, 12A /

: 230Vac, 50Hz, 6A, +/-10%

: 250 Vrms / Vdc maximum

: 92.5 liter

: 462.5 liter

: (8 minutes)

: 1 liter / second

: 4 barG

: 2.8 liter / second

: 0.5 liter / second

: 6 mbarG

: 10 mbarG

: 0.6 liter / minute

: 200 mbarG

84F HORSEBLOCK RD.

YAPHANK, NY 11980

U.S.A.

TEL: 1-631-345-3434

- THIS ENCLOSURE NORMALLY CONTAINS INSTRUMENT AIR AND

CAN RELEASE FLAMMABLE SUBSTANCES

- DO NOT OPEN THIS CABINET WHEN AN EXPLOSIVE ATMOSPHERE

IS PRESENT

- DO NOT USE THE OVERRIDE SWITCH WHEN AN EXPLOSIVE

ATMOSPHERE IS PRESENT

- TO PREVENT THE RISK OF ELECTROSTATIC SPARKING, THE VIEWING

PORT SHALL BE CLEANED ONLY WITH A DAMP CLOTH

WARNING

84F HORSEBLOCK RD.

YAPHANK, NY 11980

U.S.A.

TEL: 001-631-345-3434

- THIS ENCLOSURE NORMALLY CONTAINS INSTRUMENT AIR AND

CAN RELEASE FLAMMABLE SUBSTANCES

- DO NOT OPEN THIS CABINET WHEN AN EXPLOSIVE ATMOSPHERE

IS PRESENT

- DO NOT USE THE OVERRIDE SWITCH WHEN AN EXPLOSIVE

ATMOSPHERE IS PRESENT

- TO PREVENT THE RISK OF ELECTROSTATIC SPARKING, THE VIEWING

PORT SHALL BE CLEANED ONLY WITH A DAMP CLOTH

WARNING

1725

TYPE/MODEL

HAZARDOUS AREA PROTECTION DEGREE

CATEGORY

CERTIFICATE

SERIAL No.

POWER SUPPLY

Um:

PURGED ENCLOSURE VOLUME

MINIMUM PRE PURGE VOLUME

MINIMUM PURGE DURATION

MAXIUM ENCLOSURE LEAKAGE RATE

MINIMUM PURGE SUPPLY PRESSURE

MINIMUM PRE PURGE FLOW

MINIMUM FLOW DURING OPERATION

MIN. OVERPRESSURE DURING OPERATION

MAX. OVERPRESSURE DURING OPERATION

MAXIMUM PROCESS GAS FLOW

MAXIMUM PROCESS GAS PRESSURE

c) a restriction that the flammable substance oxygen concentration must not exceed 2%.

d) a restriction that the flammable substance shall not have a UEL higher than 80%.

: WIM 9610:

Ex ib px llC T3 Gb Ta=+5C to 45C, lP66.

: ll 2G

: FM11ATEX0006X

: XXXX

: 115Vac, 60Hz, 12A /

: 230Vac, 50Hz, 6A, +/-10%

: 250 Vrms / Vdc maximum

: 92.5 liter

: 462.5 liter

: (8 minutes)

: 1 liter / second

: 4 barG

: 2.8 liter / second

: 0.5 liter / second

: 6 mbarG

: 10 mbarG

: 0.6 liter / minute

: 200 mbarG

1.