HT instruments HT157 User Manual

Page 12

Advertising
background image

HT155 - HT157

EN - 10

Line 1

On the left side of the line there is the voltage battery and on the right
side the back-up battery voltage. In case the voltage value is > 10V, the
message “Over” will appear on the display

Line 2

In this line, it is possible to select the name of measurement as a
reference for the data saved during the operation, choosing among a list
of names, which can be created by the user (see § 4.6.3), using the “

and “

” keys. The indication “@ 1” for example is the indication of the

first name available in the list

Line 3

In this line it is possible to define, by using the “

” and “

” keys, a

criterion for the choice of the measure name. In particular, two modes are
available:

Auto mode  the measure name is automatically changed by the

instrument each time a new measurement is started

Manual mode  the measure name is not changed automatically by

the instrument and only the user can make the change

Line 4

By using the “

” and “

” keys, it is possible to select the options:

 Option No  the instrument directly starts measuring when the “

key is pressed

 Option Yes  before starting measuring, the instrument accesses the

Setup section when the “

” key is pressed, so that the parameters

can be checked and/or changed. When the “

” key is pressed, the

instrument starts measuring. This option is not available for the
“24Hours” operating mode

Line 5

In this line it is possible to select, by means of the “

” and “

” keys, a

delay time (max 10s) for the activation of measurement after the “

key is pressed. Value “0” indicates no delay. This option is not
available for the “24Hours” operating mode

Line 6

In this line, by means of the “

” and “

” keys, it is possible to activate

(On) or deactivate (Off) the print of the values shown on the display by
means of a mini-printer connected to the RS-232 output, by pressing the

” key. This function is not available

Line 7

In this line it is possible to set the total measuring time, from 1s to 24
hours. The instrument allows rapidly setting, by means of the “

” and

” keys, the following 12 preset levels: 10s, 1min, 5min, 10min, 15min,

20min, 30min, 1h, 2h, 4h, 8h, 24h, or it is possible to set the desired
value by using the “ ” and “

” keys to move to the “h”, “m” or “s” fields

and the “

” and “

” keys to set the values

Line 8

This line contains the date of the instrument’s Fw version

Advertising
This manual is related to the following products: