HT instruments HT32 User Manual

Page 21

Advertising
background image

HT32

EN - 20

Resistance

Range

Resolution

Accuracy

Open voltage

Overload protection

600.0

0.1

(0.7rdg+2dgt)

1.3V

600V rms

6.000k

0.001k

60.00k

0.01k

600.0k

0.1k

6.000M

0.001M

(1.0rdg+2dgt)

60.00M

0.01M

(1.5rdg+2dgt)


Diode test

Range

Resolution

Accuracy

(0.4  0.8V)

Test

current

Open

voltage

Overload protection

10mV

(1.5rdg+5dgt)

1.5mA

<3V

600V rms


Continuity test

Range

Buzzer

Overload protection

R<500

600V rms


Capacitance

Range

Resolution

Accuracy

Overload protection

6.000nF

0.001nF

(1.9rdg+8dgt)

600V rms

60.00nF

0.01nF

600.0nF

0.1nF

6.000F

0.001F

60.00F

0.01F

600.0F

0.1F

6.000mF

0.001mF


6.1.1. Electrical specifications
Conversion:

TRMS

Measuring rate:

1.5 times per second

Temperature coefficient:

0.15×(accuracy)/°C (<18°C and >28°C)

NMRR Normal Mode Rejection Ratio:

> 50dB for DC parameters and 50/60Hz

CMRR Common Mode Rejection Ratio: >100dB from DC up to 60Hz on DCV

> 60dB from DC up to 60Hz on ACV


6.1.2. Safety
The instrument complies with:

EN 61010-1

Insulation:

class 2, double insulation

Pollution degree:

2

Overvoltage category:

CAT IV 600V, CAT III 1000V (V//A)

CAT IV 500V (A)

For indoor use, max height:

2000m

Advertising