M70

EN - 16

6.1.1. Electrical
Conversion: Average

value

Display refreshing rate:

2 times per second


6.1.2. Safety

standards

The instrument complies with:

IEC/EN61010-1, IEC/EN61557-1-2-4

Insulation:

double insulation

Pollution level:

2

Max height of use:

2000m ; 6562ft

Measurement category:

CAT III 550V (phase to earth)

CAT III 550V (phase to phase)


6.1.3. General

specifications

Mechanical features
Dimensions (L x W x H):

240 x 100 x 45mm ; 9 x 4 x 2in

Weight (batteries included):

450g ; 16ounces

Power supply
Battery type:

4x1.5V batteries type AA LR6 AM3 MN 1500

Low battery indication:

symbol "

" is displayed

Battery life:

Multimeter:

About 50 hours

Lo

:

> 1000 tests @ 1

M

 250V:

> 1000 tests @ 480k

M

 500V:

> 1000 tests @ 480k

M

 1000V:

> 1000 tests @ 480k

Display
Features:

4 LCD with max. reading 9999 counts + symbol
and decimal point

6.2. ENVIRONMENT
6.2.1. Environmental

conditions

Reference temperature:

23°C ± 5°C ; 73°F ± 41°F

Working temperature:

0°C ÷ 40°C ; 32°F ÷ 104°F

Relative humidity allowed:

<70% RH

Storage temperature:

-10° ÷ 60° C ; 14°F ÷ 140°F

Storage humidity:

<70% RH

This instrument complies with the requirements of the European Low Voltage

Directive 2006/95/CE (LVD) and EMC Directive 2004/108/CE


6.3. ACCESSORIES
6.3.1. Standard

accessories

 Set of 2 R/B cables, 1.5m + 2 R/B alligator clips + 1 R test lead

 Batteries

 Carrying

bag

 Certificate of test

 User

manual