Figure b-7. current:triggered command, Figure b-8. current:triggered query, Curren – KEPCO BIT 232F User Manual

Page 43: Curr:trig

Advertising
background image

BIT 232 022800

B-5

FIGURE B-7. CURRent:TRIGgered COMMAND

FIGURE B-8. CURRent:TRIGgered QUERY

Syntax:

Short Form:

CURR:TRIG <value>

Long Form:

[SOURce]:CURRent:TRIGgered <value>

Function:

Programs current value to be implemented by *TRG command. Actual output current will depend on
load conditions.

Description:

This command can be used to reset many power supplies to preselected parameters by issuing a sin-
gle *TRG command.

Example:

VOLT 21; CURR 1.1

Power supply commanded to go to 21V, 1.1A

CURR:TRIG 2.3

Power supply current programmed to 2.3A upon receipt of *TRG

CURR?

Controller reads 1.1, indicating programmed current value = 1.1A

*TRG

Power supply commanded to current value established by CURR:TRIG
command (2.3) and voltage value established by VOLT:TRIG

CURR?

Controller reads 2.3, indicating programmed current value = 2.3A

CURR:TRIG

Syntax:

Short Form:

CURR:TRIG?

Long Form:

[SOURce]:CURRent:TRIGgered?

Function:

Returns value to controller which represents current value to be programmed by *TRG command.

Description:

This command returns the current value established by CURR:TRIG command.

Example:

VOLT 21; CURR 1.1

Power supply commanded to go to 21V, 1.1A

CURR:TRIG 2.3

Power supply current programmed to 2.3 upon receipt of *TRG

CURR?

Controller reads 1.1, indicating programmed current value = 1.1A

CURR:TRIG?

Controller reads 2.3 (current value established by CURR:TRIG
command

CURR:TRIG?