Electrical connections – KROHNE OPTISONIC 7300 EN User Manual

Page 45

Advertising
background image

ELECTRICAL CONNECTIONS

4

45

OPTISONIC 7300

www.krohne.com

09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en

Status output / limit switch active, modular I/Os

• Observe connection polarity.
• U

int

= 24 VDC

• I ≤ 20 mA
• R

L

≤ 47 kΩ

• open:

I ≤ 0.05 mA
closed:
U

0, nom

= 24 V at I = 20 mA

• X designates the connection terminals A, B or D, depending on the version of the signal

converter.

Status output / limit switch passive, modular I/Os

• Any connection polarity.
• U

ext

= 32 VDC

• I ≤ 100 mA
• R

L, max

= 47 kΩ

R

L, min

= (U

ext

- U

0

) / I

max

• open:

I ≤ 0.05 mA at U

ext

= 32 VDC

closed:
U

0, max

= 0.2 V at I ≤ 10 mA

U

0, max

= 2 V at I ≤ 100 mA

• The output is open when the device is de-energized.
• X designates the connection terminals A, B or D, depending on the version of the signal

converter.

Figure 4-16: Status output / limit switch active S