Operation – KROHNE OPTISONIC 7300 EN User Manual

Page 80

Advertising
background image

6

OPERATION

80

OPTISONIC 7300

www.krohne.com

09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en

C5.….7

format 1.line

Specify decimal places.

Select: automatic (adaptation carried out automatically) /

X (= none) …X.XXXXXXXX (max. 8 digits)

C5.….8

measurement 2.line

Specify measurement 2

nd

line

(only available if this 2

nd

line is activated)

Select: bar graph (for the measurement selected in 1

st

line) / volume

flow / corr. volume flow / mass flow / molar mass / flow speed /

velocity of sound / gain / diagnostics 1, 2, 3 / counter 1, 2, 3 / bargraph /

operating hours

C5.….9

format 2.line

Specify decimal places.

Select: automatic (adaptation carried out automatically) /

X (= none) …X.XXXXXXXX (max. 8 digits)

C5.….10 measurement 3.line

Specify measurement 3

rd

line

(only available if this 3

rd

line is activated)

Select: volume flow / corr. volume flow / mass flow / molar mass / flow

speed / velocity of sound / gain / diagnostics 1, 2, 3 / counter 1, 2 /

operating hours

C5.….11 format 3.line

Specify decimal places.

Select: automatic (adaptation carried out automatically) /

X (= none) …X.XXXXXXXX (max. 8 digits)

C5.5

graphic page

C5.5.1

select range

Graphic page always shows trend curve of the measurement of the 1

st

page / 1

st

line, see Fct. C5.3.2.

Select: manual (set range in Fct. C5.5.2)

Automatic (automatic depiction based on the measured values)

Reset only after parameter change or after switching off and on.

C5.5.2

range

Set the scaling for the Y axis.

Only available if "manual" is set in C5.5.1.

+xxx ±xxx%

Range: -100…+100%

1

st

value = lower limit / 2

nd

value = upper limit

Condition: 1

st

value ≤ 2

nd

value

C5.5.3

time scale

Set the time scaling for the X axis, trend curve.

xxx min

Range: 0…100 min

C5.6

special functions

C5.6.1

reset errors

Reset?

Select: no/yes

C5.6.2

save settings

Save current settings.

Select: cancel (exit function without saving) / backup 1 (save in storage

location 1) / backup 2 (save in storage location 2)

Query: go on with copy? (can not be undone).

Select: no (exit function without saving) / yes (copy current settings to

storage backup 1 or backup 2)

Advertising