INSTALLATION
2
17
OPTIWAVE 7300 C
www.krohne.com
03/2014 - 4000050005 - QS OPTIWAVE 7300 R08 en
• Make sure that the tank connection is level.
• Make sure that you use the applicable gasket for the connection dimensions and the process.
• Align the gasket correctly.
• Lower the antenna carefully into the tank.
• Turn the nut on the device process connection to attach the device to the tank.
• Tighten the connection.
i
Refer to local rules and regulations for the correct torque to apply to the connection.
SMS
Equipment needed:
• Device
• Gasket (not supplied)
• SMS nut
• Make sure the tank connection is level.
• Make sure that you use the applicable gasket for the connection dimensions and the process.
• Align the gasket correctly.
• Lower the antenna carefully into the tank.
• Turn the nut on the device process connection to attach the device to the tank.
• Tighten the connection.
i
Refer to local rules and regulations for the correct torque to apply to the connection.
Figure 2-20: SMS connection
1 Tank socket
2 Nut for SMS connection