Field Diagnostics of "F Configuration"

(31) (30) (26) (25)

(21)

Setting:

(02) IO B Binary Output Config / (03) IO B Current In-/Output

Config / (04) IO A Binary Output Config / (05) IO A Current In-

/Output Config. / (10) IO2 Configuration /

(11) IO1 Configuration / (12) Display Config. /

(21) Fieldbus Config. / (25) Density Calibration /

(26) Process Input Config. / (30) DM Configuration / (31) BM

Configuration

FD_EXTENDED_

FD_EXTENDED_

FD_EXTENDED_

FD_EXTENDED_

MAP_30

MAP_30

MAP_30

MAP_30

FD_EXTENDED_

MAP_30

R/W

Field Diagnostics of "F Electronics"

(31) (28) (27) (26)

(21) (16)

Setting:

(01) IO B Failure / (02) IO A Failure / (07) IO 2 Failure / (08) IO 1

Failure / (16) Fieldbus Failure / (21) Process Input Failure /

(26) DM Failure / (27) BM Failure / (28) HW Combination

Error / (31) System Error

FD_EXTENDED_

FD_EXTENDED_

FD_EXTENDED_

FD_EXTENDED_

MAP_31

MAP_31

MAP_31

MAP_31

FD_EXTENDED_

MAP_31

R/W

Field Diagnostics of "F Sensor"

(31) (30)

Setting:

(30) Sensor Error / (31) Sensor Containment Dam.

FD_MAINT_ACTIVE

FD_MAINT_ACTIVE

FD_MAINT_ACTIVE

FD_MAINT_ACTIVE

Maintenance Active

R

This parameter reflects the error conditions that are being

detected as active as selected for this category. It is a bit

string, so that multiple conditions may be shown. See section

2.9.

Uninitialized

Setting:

(00) Check / (01) Electronics : Operation Info /

(02) Config: NoMeas.Value / (08) Electronics : Power Fail /

(09) Process: System Control / (10) Configuration : Totaliser /

(11) Process : Signal Low / (12) Process : 2 Phase Flow /

(13) Process : Signal Search / (14) Electronics : IO

Connection / (15) Process : Current input / (16) M Process /

(17) M Configuration / (18) M Electronics / (19) M Sensor /

(20) S Process / (21) S Configuration / (22) S Electronics /

(23) S Sensor / (24) C Process / (25) C Configuration /

(26) C Electronics / (27) C Sensor / (28) F Process /

(29) F Configuration / (30) F Electronics / (31) F Sensor

FD_MAINT_ALM

FD_MAINT_ALM

FD_MAINT_ALM

FD_MAINT_ALM

Fail Maintenance

Alarm

This parameter is used primarily to broadcast a change in the

associated active conditions, which are not masked, for this

alarm category to a Host System.

Unacknowledged

R/W

A discrete enumeration which is set to "Unacknowledged"

when an alarm occurs, and set to "Acknowledged" by a write

from a human interface device or other entity which can

acknowledge that the alarm/event has been noticed.

Uninitialized

Setting:

Uninitialized / Acknowledged / Unacknowledged

Alarm State

R

A discrete enumeration which gives an indication of whether

the alert is active and whether it has been reported.

Uninitialized

Setting:

Uninitialized / Clear - reported / Clear - not reported / Active -

reported / Active - not reported

Time Stamp

R

The time when evaluation of the block was started and a

change in alarm/event state was detected that is unreported.

The time stamp value will be maintained constant until alert

confirmation has been received - even if another change of

state occurs.

Uninitialized

Setting:

MM / DD / YY (Month / Day / Year)

HH:MM:SS (Hour:Minute:Second)

Subcode

R

An enumeration specifying the cause of the alert to be

reported.

-

Parameter

Parameter

Parameter

Parameter
DD name

Access

Description and settings

Initial Value