Operation – KROHNE MFC 400 FOUNDATION FIELDBUS User Manual

Page 61

Advertising
background image

OPERATION

4

61

MFC 400

www.krohne.com

11/2013 - 4003221901 - AD MFC 400 FF R01 en

Update State

R

A discrete enumeration which gives an indication of whether

the alert has been reported.

Uninitialized

Setting:

Uninitialized / Reported / Not Reported

Time Stamp

R

The time when evaluation of the block was started and a

change in alarm/event state was detected that is unreported.

The time stamp value will be maintained constant until alert

confirmation has been received - even if another change of

state occurs. Time stamp records the time when parameter

was updated.

Uninitialized

Setting:

MM / DD / YY (Month / Day / Year)

HH:MM:SS (Hour:Minute:Second)

Static Revision

R

The static revision of the block whose static parameter was

changed and is being reported. It is possible for the present

value of static revision to be greater than this because static

can be changed at any time.

0

Setting:

0…65535

Relative Index

R

The OD index of the static parameter whose change caused

this alert, minus the FB starting index. If the update event was

caused by a write to multiple parameters at the same time,

then this attribute will be zero.

0

Setting:

0…65535

COLLECTION_

COLLECTION_

COLLECTION_

COLLECTION_

DIRECTORY

DIRECTORY

DIRECTORY

DIRECTORY

Collection

Directory

A directory that specifies the number, starting indices and DD

Item IDs of the data collections in each transducer within a

Transducer Block.

-

PRIMARY_VALUE_

PRIMARY_VALUE_

PRIMARY_VALUE_

PRIMARY_VALUE_

301

301

301

301

Drive Level

The measured drive level value and status of available to the

Function Block. (Fct. B2.11)

-

STATUS

Status

R

Digital transducers, unlike their analogue versions, can detect

faults that make the measurement bad or prevent the

actuator from responding. This additional, valuable

information will be passed along with each transmission of a

data value in the form of a status attribute.

-

VALUE

Value

R

A numerical quantity entered by a user or calculated by the

algorithm.

-

PRIMARY_VALUE_

PRIMARY_VALUE_

PRIMARY_VALUE_

PRIMARY_VALUE_

RANGE_301

RANGE_301

RANGE_301

RANGE_301

Drive Level Range

The high and low range limit values, the engineering units

code and the number of digits to the right of the decimal point

to be used to display the Primary Value.

-

EU_100

max value

R

The engineering unit value which represents the upper end of

range of the associated Block Parameter.

100.0

EU_0

min value

R

The engineering unit value which represents the lower end of

range of the associated Block Parameter.

0.0

UNITS_INDEX

Units Index

R/W

Device Description units code index for the engineering unit

descriptor for the associated block value.

%

Settings:

Drive Level units:

Drive Level units:

Drive Level units:

Drive Level units:

%

DECIMAL

Decimal

R

The number of digits to the right of the decimal point which

should be used by an interface device in displaying the

specified parameter.

2

PRIMARY_VALUE_

PRIMARY_VALUE_

PRIMARY_VALUE_

PRIMARY_VALUE_

302

302

302

302

Sensor Average

The measured value and status available to the Function

Block.

-

Parameter

Parameter

Parameter

Parameter
DD name

Access

Description and settings

Initial Value