KROHNE UFC 500 HART User Manual

Page 17

Advertising
background image

HARTô Smart Communications Protocol

UFC500 Command Specification Rev: 2.0 Release Date: 9 Jun 2001

© 2001 KROHNE Mefltechnik D-47058 Duisburg

Page

17

8.3

Command #132

Read Frequency/Pulse Output Damping Control

Returns the control variable for the damping to be used on device frequency/pulse output.

REQUEST DATA BYTES

NONE

RESPONSE DATA BYTES

#0

#1

Ö

#13

PULSE

FW IDENT

FW IDENT

DAMPING

NUMBER

NUMBER

CONTROL

#14

Ö

#23

RELEASE

RELEASE

DATE

DATE

Data Byte #0

Damping control for the frequency/pulse output:
0 - Damping value is fixed to 40 ms,
1 - The same as for current output (Primary Variable Damping Value).

Data Byte #1..#13

Device firmware identification number, ASCII, e.g. м 6.97.002.87 м.

Data Byte #14..#23

Device release date, ASCII, e.g. м09.07.2001о .

COMMAND-SPECIFIC RESPONSE CODES

0

No Command-Specific Errors

1-5

Undefined

6

Local Device User

7-127

Undefined

Advertising