KROHNE UFC 500 HART User Manual
Page 17
HARTô Smart Communications Protocol
UFC500 Command Specification Rev: 2.0 Release Date: 9 Jun 2001
© 2001 KROHNE Mefltechnik D-47058 Duisburg
Page
17
8.3
Command #132
Read Frequency/Pulse Output Damping Control
Returns the control variable for the damping to be used on device frequency/pulse output.
REQUEST DATA BYTES
NONE
RESPONSE DATA BYTES
#0
#1
Ö
#13
PULSE
FW IDENT
FW IDENT
DAMPING
NUMBER
NUMBER
CONTROL
#14
Ö
#23
RELEASE
RELEASE
DATE
DATE
Data Byte #0
Damping control for the frequency/pulse output:
0 - Damping value is fixed to 40 ms,
1 - The same as for current output (Primary Variable Damping Value).
Data Byte #1..#13
Device firmware identification number, ASCII, e.g. м 6.97.002.87 м.
Data Byte #14..#23
Device release date, ASCII, e.g. м09.07.2001о .
COMMAND-SPECIFIC RESPONSE CODES
0
No Command-Specific Errors
1-5
Undefined
6
Local Device User
7-127
Undefined