KYORITSU 3126 User Manual

Page 10

Advertising
background image

̶ 8 ̶

●Overload protection: Insulation resistance range: AC1200V/10sec.

Voltage range: AC720V/10sec.

●Withstand voltage:

AC5320V(50/60Hz)/5sec.

(Between electrical circuit and enclosure)

●Insulation resistance: 1000MΩ or more/DC1000V

(Between electrical circuit and enclosure)

●Dimension:

205(L)×152(W)×94(D)mm

●Weight:

approx. 1.8kg (battery included)

●Power source:

DC12V: Alkaline battery size C(LR14)x 8pcs

●Current consumption (representative values at 12V of supply voltage)

Range

500V

1000V 2500V 5000V

V

AC/DC

Output at
short-circuit

For 10 sec after a test is started :
850mA, after that : 150mA

110mA
* at voltage
measurement

When rated
measuring current
is outputted

450mA

/0.5MΩ

500mA

/1MΩ

600mA

/2.5MΩ

850mA

/5MΩ

Output at
open circuit

45mA

50mA

70mA 110mA

On stand-by

25mA

110mA

When backlight
is on

Increased by 30mA

Note) Current values in above table are all approximate values.

●Operating time:

approx. 10 hours continuous

-

under a load of 100MΩ at 5000V Insulation
resistance range

●Accessories:

Line probe: MODEL7165A

Earth cord: MODEL7224A

Guard cord: MODEL7225A

Alkaline size C battery (LR14) x 8pcs

Instruction manual

Hard Case MODEL9159

Pickel Type Prod: MODEL8019

Straight Type Prod: MODEL8254

●Optional accessories: Adaptor for recorder MODEL8302

Line probe with alligator clip MODEL7168

Advertising