KYORITSU 4106 User Manual

Page 20

Advertising
background image

16

Settings of following parameters can be made on this instrument
● Wire

: Measurement method (Wiring System)

● Freq

: Measurement frequency

● Site

: Site (location) No

● Lh

: Interval of the auxiliary earth spikes at Earth resistivity (ρ)

measurement

● Date/Time : Year/ Month/ Day, Time (24-hour display)
● Rk

: Residual resistance on the Test Leads

8-2-2 Setting for Measurement Method
Measurement method is selectable from: 2-wire (2-wire system), 3-wire
(3-wire system),4-wire (4-wire system) and ρ”(earth resistivity).

Select “Wire” with the Cursor Key on the CONFIG_SETTING Screen and
press the “

” Key to proceed to the Wiring Setting Screen. (Fig.9)

Select the appropriate Wiring System with the Cursor Key and press the

” Key. Then the CONFIG_SETTING Screen with the selected Wiring

System will be displayed .

8-2-3 Setting for Measurement Frequency
Measurement signal frequencies can be selected from following four
frequency bands with this instrument in order to minimize the influence of
the series interference voltage (earth voltage).
*Auto *94Hz *105Hz *111Hz *128Hz
The instrument automatically select the best suitable frequency when
selecting “Auto” and output the frequency signal. Select “Freq” with the
Cursor Key on the CONFIG_SETTING Screen and press the “

” Key to

display the Frequency Setting Screen (Fig.11).

Fig. 9

Fig. 10

Fig. 11

Advertising