2 live circuit warning – KYORITSU 4300 User Manual

Page 16

Advertising
background image

̶ 14 ̶

(3) The measured voltage is displayed on the LCD.

Take the reading without pressing the Test button. The

instrument judges DC or AC and shows “DC” or “AC” sign on the

LCD.

* When negative DC voltages are detected at the H+S(C+P)

terminal, the negative polarity sign “-“ appears to the left of the

measured value.

* The LCD does not show “DC”, “AC” nor sign when the

measured values are less than 5V.

The LCD shows “>314.9V” when the measured value exceeds

the display range (over range) and it shows “-OL” for negative DC

voltages.

7-2 Live circuit warning

The warning LED starts blinking red with audible warning when the

measured value is 30V or higher.

* The instrument does not carry out resistance measurements

even the Test button is held down while the live circuit warning is

activating.

LED starts blinking. (Red)

Fig. 7-3

Advertising