Open Circuit

Voltage(DC)

Short Circuit

Current

Range

Accuracy

Greater than 4V

Greater than

200mA

20/200Ω

Auto-Ranging

Up to 2Ω

Over 2Ω

±(3%rdg+4dgt)
±(3%rdg+3dgt)

3. SPECIFICATION

Measurement Specification

Operating range(as in IEC61557) 20Ωrange:0.2Ω∼19.99Ω/200ΩRange:20Ω∼199.9Ω

Continuity (to IEC61557-4)

Insulation Resistance (to IEC61557-2)

Loop Impedance (to IEC61557-3)

RCD testing (to IEC61557-6)

Operating range(as in IEC61557) 20MΩ Range:0.5MΩ∼19.99MΩ/200MΩ Range:20MΩ∼100MΩ

Open Circuit

Voltage (DC)

500V +20%−0%

Rated Current

1mA or greater

@ 500kΩ

Range

20/200MΩ

Auto-Ranging

Accuracy

±(3% rdg +3dgt)

Rated Voltage

(AC)

230V+10%−15%

50Hz

Nominal Test

Current at 0Ω

External Loop

25A/10ms

15mA/350ms max.

Range

20Ω

2000Ω

Accuracy

±(3%rdg +8dgt)
±(3%rdg +8dgt)

Function

RCD × 1/2

RCD × 1

FAST

Rated Voltage

(AC)

230V+10%−15%

50Hz

Trip Current

Settings

10/30/100/300/

500mA

150mA

Trip Current

Duration

2000ms

50ms

Accuracy

Trip Current:

−8% ∼−2%

Trip Current:

+2% ∼+8%

Trip Time

±(1%rdg+3dgt)

Operating range(as in IEC61557) 20Ω Range:2Ω∼19.99Ω/2000Ω Range:100Ω∼1999Ω

Rated Voltage
100∼250V 50Hz

Measuring Range

100∼250V 50Hz

Accuracy

3%rdg

Voltage Measurement