TROUBLESHOOTING CHART (CONTINUED)

Malfunction:

Window tube is cracking or crazing.

Possible Cause:

Using incompatible cleaning solution
on Lexan window tube.

Corrective Action:

Use soap & water or a mild degreaser
(Stoddard or Naptha) to clean Lexan
tube. To check the compatibility of
your cleaning fluid, call General
Electric’s Lexan Compatibility
Reference line at 800-845-0600.

Malfunction:

Scale is fogging or coming loose.

Possible Cause:

Ambient or fluid temperature is too
high.

Corrective Action:

Relocate meter in another area where
temperature specifications are not being
exceeded.

Possible Cause:

Using incompatible cleaning solvents
on scale.

Corrective Action:

Use soap and water.