2000 hz pulse output connections – Lake Monitors Flow Transmitters User Manual

Page 34

Advertising
background image

0-2000 Hz Pulse Output Connections

Wiring Instructions (Refer to Illustrations 6 and 7 above):

1) Move the programmable jumper on the circuit board into the

position closest to the meter’s inlet, as shown in Illustration 7.

2) Connect the positive voltage source (+12 to +35 VDC) to terminal

#1 of the din connector.

3) Connect terminal #2 of the din connector to the negative side

of the DC voltage source.

4) Connect the “G” terminal of the din connector to the pulse input

of the receiving device.

5) If the power source does not originate at the receiving device, a

wire will need to be connected between the negative side of the
voltage source and the signal ground of the receiving device.

6) If the transmitter is operating properly, the green LED on the circuit

board will illuminate brightly when power is applied to the unit.

Page 34 / Flow Transmitters / Lake Manual

Illustration 6

Illustration 7

PROGRAMMABLE JUMPER
IN POSITION CLOSEST
TO METER INLET

JUMPER POSITION - 0-2000Hz PULSE OUTPUT

NO CONNECTION

ELECTRICAL CONNECTIONS - 0-2000Hz OUTPUT

“G” PIN

0-2000Hz OUTPUT

PIN #1

+12 - 35 VDC

PIN #2
DC GROUND

Advertising