4 typical system installations – Rola-Chem 554000 ORP/pH Digital Controller User Manual

Page 18

Advertising
background image


7.4 Typical System Installations


TYPICAL SODIUM HYPOCHLORITE FEED SYSTEM

WATER

FROM
POOL

*SAFETY FLOWSWITCH FOR

PROTECTION OF HEATER AND

TO ENSURE DILUTION OF
CHEMICAL INTO POOL.

POOL
PUMP

BASKET

***FILTER

WATER
TO

POOL

EARTH
GROUND

*** OPTIONAL FILTER TO

HELP KEEP MANIFOLD

AND PROBES CLEAR OF

DEBRIS.

HEATER

*FLOWSWITCH

**FLOWSWITCH

FILTER

CONTROLLER

ELECTRICAL OUTLET
CONTROLLED BY
CIRCULATION SYSTEM

CHLORINE
NaOCl

CHLORINE
PUMP

ACID

PUMP

MANIFOLD

ACID

HCl

** SAFETY FLOWSWITCH TO ENSURE
CIRCULATION TO CONTROL PROBES
AND INDICATOR THAT POOL
CIRCULATION IS OCCURRING.

*** OPTIONAL FILTER TO

HELP KEEP MANIFOLD

AND PROBES CLEAR OF

DEBRIS.

SYSTEM USING EROSION FEEDER (TRI-CHLOR/ DI-CHLOR) WITH SODA ASH PUMP

HEATER

EROSION
FEEDER

EARTH
GROUND

WATER

FROM
POOL

**SAFETY FLOWSWITCH TO ENSURE
CIRCULATION TO CONTROL PROBES
AND INDICATOR THAT POOL
CIRCULATION IS OCCURRING.

*SAFETY FLOWSWITCH FOR

PROTECTION OF HEATER AND

TO ENSURE DILUTION OF
CHEMICAL INTO POOL.

POOL
PUMP

***FILTER

FILTER

*FLOWSWITCH

CHECK

VALVE

STRAINER

**FLOWSWITCH

ELECTRICAL
OUTLET
CONTROLLED BY
CIRCULATION
SYSTEM

MANIFOLD

SOL. VALVE
(120 V.)

CONTROLLER

pH PUMP

TIMED FEED

WATER
TO

POOL

EARTH
GROUND

SODA

ASH

MIXER

pH
SOLUTION

Rola-Chem Digital Controller PN 554102 6/01/2012 Page: 18 of 20